pyrotec A30 animal cremator
design
The Pyrotec A30 is a modern incinerator designed to burn animal carcass waste in an efficient, clean and environmentally safe manner. Using the Pyrolytic principle of combustion, it is particularly suited for small animal carcasses. This model is specifically for burning domestic pets and animal remains and is equipped with the necessary sophistication of control, secondary chamber volume, manual loading and chimney.
models
A30(1), A30(2), A30(3)
waste type
Animal Carcass waste – calorific value 1,000 kcal/kg, density 700 kg/m³, moisture content 85%.
construction
Mild steel fabrication construction using 5mm steel plate suitability braced and stiffened.
refractory
Primary Chamber
Hot face material 1,600°C quality 100mm thick, backed by 25mm ceramic fibre insulation.
Secondary Chamber
Hot face material 1,600°C quality 100mm thick backed by 25mm ceramic fibre insulation.
Hearth
High standard 1,600°C, 100mm thick backed by 38mm calcium silicate insulation.
fuel
Natural gas, LP gas or 35 seconds fuel oil.
electrical supply
380/440 volt, 3 phase, 50/60hz
230 volt, 1 phase, 50/60hz
burners
Automatic package burners complete with electric ignition and flame failure control complete with all necessary valves, motors and integral continuous running fan. Automatically temperature controlled to provide optimum combustion conditions, primary and secondary chamber temperatures and fuel economy.
Primary Chamber – one at 185,000 kcal/hr on/off control
Secondary Chamber – one at 185,000 kcal/hr on/off control
standard
EU Animal by Product Regulation EC1774/2002
UK Animal by Product Regulation 2005
DEFRA Type Approved
Secondary Chamber Residence time: - 2.0 seconds at 850°C
fans
All combustion and cooling air is provided by a common automatically controlled centrifugal fan, which provides air to nozzles strategically, located throughout the combustion chambers to ensure optimum conditions.
finish
One coat of primer followed by one coat of enamel finish in red.
control panel
Automatic control system built to IEC standards incorporating relay control, providing all automatic plant functions and incorporating the following sequences.
1) Preheat cycle
2) Burn cycle
3) Cool down cycle
monitors
The standard control system provides a digital display of the primary and secondary chamber temperatures; however, in some instances the local DEFRA official may require the temperature to be permanently recorded by a dedicated chart recorder.
loading/ash removal door
A full size manually operated access door for waste loading/deashing.
Pyrotec model |
||||
A30(1) |
A30(2) |
A30(3) |
||
Capacity: |
Kg/hr |
50 |
50 |
50 |
Thermal KCal/hr |
50,000 |
50,000 |
50,000 |
|
Dimensions (m): |
A |
2.175 |
2.675 |
3.275 |
B |
1.100 |
1.100 |
1.100 |
|
C |
0.980 |
0.980 |
0.980 |
|
D |
1.800 |
1.800 |
1.800 |
|
E |
6.000 |
6.000 |
6.000 |
|
Chimney internal diameter (m) |
0.350 |
0.350 |
0.350 |
|
Manual loading door size (m) |
0.87 x 0.80 |
0.87 x 0.80 |
0.87 x 0.80 |
|
Primary chamber volume (m³) |
0.600 |
0.900 |
1.200 |
|
Secondary chamber volume (m³) |
0.420 |
0.630 |
0.880 |
|
Note :- | ||||
..